HLG

HLG is the BT.2100 transfer function (OETF + OOTF); system gamma is 1.2 at the 1000 cd/m² reference display.

Fig. 1: Display transfer function (EOTF). The horizontal axis can show the normalised code value or a quantised code value derived from bit depth and range; the vertical axis is luminance (cd/m²).

The HLG OETF is fixed: it maps scene-linear light to a 0–1 signal and does not depend on the display. Display light comes from the OOTF — F_D = α·Y_S^(γ−1)·R_S (and likewise for G and B), where α is the display’s nominal peak luminance and γ the system gamma: 1.2 at 1000 cd/m², otherwise per Note 5f of Table 5 in BT.2100. The same signal therefore produces different light on displays of different peak luminance. The curve below is the neutral axis: with equal channels Y_S equals the signal, and the OOTF reduces to a power law.

Use this space Transfer compare ↗

Sources

  1. ITU-R BT.2100-3: Parameter values for HDR television (HLG, PQ) (PDF)