von Kries
The coefficient law: XYZ into cone responses, one scale factor per channel, so the source white lands on the target white.
| Year | 1902 |
|---|---|
| First published in | von Kries 1902 |
| Cone space | Hunt–Pointer–Estevez, normalised to D65 |
Transform
The equation numbers are CIE 15:2018 Annex D's own (they write out CIECAM02's CAT02; another M changes nothing structural). D is the degree of chromatic adaptation — one scalar; D_R, D_G, D_B are the three coefficients. Different quantities, similar names.
Matrix
XYZ → cone responses
[ 0.400240000000 0.707600000000 -0.080810000000 ] [ -0.226300000000 1.165320000000 0.045700000000 ] [ 0.000000000000 0.000000000000 0.918220000000 ]
Cone responses → XYZ (inverse of M)
[ 1.859936387456 -1.129381618580 0.219897409596 ] [ 0.361191436242 0.638812463285 -0.000006370597 ] [ 0.000000000000 0.000000000000 1.089063623097 ]
Effective cone sensitivities
Solid: this transform. Dashed: Hunt–Pointer–Estevez for comparison. The curve is M applied to the CIE 1931 2° colour-matching functions, normalised per channel.
White point
Change the source or target white and the degree D; the equivalent matrix and the white-point check recompute below.
Worked example
Sample: xy = 0.25 / 0.30, Y = 20, i.e. XYZ = 16.67 / 20.00 / 30.00 (normalised to Y = 100; about sRGB #528392). Degree of adaptation D = 1 here, so the coefficients are simply the ratios of the two whites. XYZ to three decimals, coefficients to four.
| R | G | B | |
|---|---|---|---|
| 1(Rw, Gw, Bw)ᵀ = M · XYZw(D65) | 100.000 | 100.000 | 99.999 |
| 2(Rwr, Gwr, Bwr)ᵀ = M · XYZwr(D50) | 102.687 | 98.481 | 75.763 |
| 3DR = Rwr / Rw | 1.0269 | 0.9848 | 0.7576 |
| The whites go through the same M. Dividing one by the other gives the three coefficients — they depend only on the two white points, never on the colour. | |||
| 4(R, G, B)ᵀ = M · XYZ | 18.400 | 20.905 | 27.547 |
| 5Rc = DR · R(same for G, B) | 18.894 | 20.587 | 20.870 |
| 6(Xc, Yc, Zc)ᵀ = M⁻¹ · (Rc, Gc, Bc)ᵀ | 16.480 | 19.976 | 22.729 |
Reading the coefficients: D_B = 0.7576 means the blue response is multiplied by 0.7576, so 24.2% of it is discounted — D65's white is far bluer than D50's, and removing that blue is what makes the colour look the same under the warmer white. R goes the other way, times 1.0269. Note that Y_c is not Y: here 20.000 becomes 19.976, because a pure chromatic adaptation pins the white points, not every luminance.
Degree of chromatic adaptation
The law itself carries no D; folding incomplete adaptation into it is described on the basic-problems page.
The coefficient law and its modern form ¶
In 1902 von Kries proposed the coefficient law: multiply each cone response by a factor so the source white aligns with the target white. Neither CIE XYZ nor modern cone fundamentals existed in 1902; the XYZ → HPE matrix shown above is a modern implementation.
The HPE matrix comes in two normalisations: the one on this page maps D65 close to (1, 1, 1) (1.000004 / 1.000002 / 0.999995 with this site’s four-decimal xy); the CIECAM02 set (CIE 15:2018 Equation D.9) has [0, 0, 1] as its third row. In theory they differ only by a constant per row (about 1.0270 / 0.9847 / 0.9182) and the coefficient law is invariant to row scaling, so both give virtually identical adapted results (differing only slightly from matrix rounding).
Sources
- von Kries, J. (1902). Festschrift der Albrecht-Ludwigs-Universität.
- Hunt, R. W. G. (2004). The Reproduction of Colour (6th ed.). Wiley.