Bianco PC 2010

The second solution from Bianco and Schettini: a positive constraint on the cone sensitivities, pressing the negative lobes down to almost nothing.

Year2010
First published inBianco & Schettini 2010 (positive-constrained solution)
Cone spaceSharpened cone space from positive-constrained numerical optimisation

Transform

(Rw, Gw, Bw)ᵀ = M · XYZw the source white into cone space (Eq. D.1) (Rwr, Gwr, Bwr)ᵀ = M · XYZwr the reference white, likewise (Eq. D.1) DR = D · Rwr/Rw + 1 − D one per channel; at D = 1 this is just R_wr/R_w (Eq. D.2) (R, G, B)ᵀ = M · XYZ the sample, into the same space (Eq. D.14) (Rc, Gc, Bc)ᵀ = diag(DR, DG, DB) · (R, G, B)ᵀ multiplied channel by channel (Eq. D.15) (Xc, Yc, Zc)ᵀ = M⁻¹ · (Rc, Gc, Bc)ᵀ back to tristimulus values

The equation numbers are CIE 15:2018 Annex D's own (they write out CIECAM02's CAT02; another M changes nothing structural). D is the degree of chromatic adaptation — one scalar; D_R, D_G, D_B are the three coefficients. Different quantities, similar names.

Matrix

XYZ → cone responses

[ 0.648900000000 0.391500000000 -0.040400000000 ]
[ -0.377500000000 1.305500000000 0.072000000000 ]
[ -0.027100000000 0.088800000000 0.938300000000 ]

Cone responses → XYZ (inverse of M)

[ 1.312315029860 -0.399472145589 0.087157115729 ]
[ 0.379360343522 0.654530799717 -0.033891143239 ]
[ 0.001999934780 -0.073481860983 1.071481926203 ]

Effective cone sensitivities

Solid: this transform. Dashed: Hunt–Pointer–Estevez for comparison. The curve is M applied to the CIE 1931 2° colour-matching functions, normalised per channel.

White point

Change the source or target white and the degree D; the equivalent matrix and the white-point check recompute below.

Worked example

Sample: xy = 0.25 / 0.30, Y = 20, i.e. XYZ = 16.67 / 20.00 / 30.00 (normalised to Y = 100; about sRGB #528392). Degree of adaptation D = 1 here, so the coefficients are simply the ratios of the two whites. XYZ to three decimals, coefficients to four.

RGB
1(Rw, Gw, Bw)ᵀ = M · XYZw(D65)96.425102.512108.491
2(Rwr, Gwr, Bwr)ᵀ = M · XYZwr(D50)98.390100.08983.686
3DR = Rwr / Rw1.02040.97640.7714
The whites go through the same M. Dividing one by the other gives the three coefficients — they depend only on the two white points, never on the colour.
4(R, G, B)ᵀ = M · XYZ17.43521.97729.473
5Rc = DR · R(same for G, B)17.79021.45822.735
6(Xc, Yc, Zc)ᵀ = M⁻¹ · (Rc, Gc, Bc)ᵀ16.75620.02322.819

Reading the coefficients: D_B = 0.7714 means the blue response is multiplied by 0.7714, so 22.9% of it is discounted — D65's white is far bluer than D50's, and removing that blue is what makes the colour look the same under the warmer white. R goes the other way, times 1.0204. Note that Y_c is not Y: here 20.000 becomes 20.023, because a pure chromatic adaptation pins the white points, not every luminance.

Degree of chromatic adaptation

D = 1. The paper's corresponding-colour experiment assumes complete adaptation; for incomplete adaptation, the CIECAM02 D formula can be applied.

The paper gives two matrices. The first is the unconstrained numerically optimised solution (see the Bianco–Schettini page); the second is the positive-constrained (PC) solution on this page. Both optimise the same objective — make the transform’s predicted corresponding colours match the experimental data — and differ only in the constraint.

unconstrained  [ 0.8752  0.2787 -0.1539 ]
               [ -0.8904 1.8709  0.0195 ]
               [ -0.0061 0.0162  0.9899 ]

PC             [ 0.6489  0.3915 -0.0404 ]
               [ -0.3775 1.3055  0.0720 ]
               [ -0.0271 0.0888  0.9383 ]

The matrix itself still contains negative entries — sharpened cone spaces generally need them to separate the channels. The paper adds a negative-response penalty during optimisation to push the three CIE 1931 2° spectral sensitivity curves nearly above zero, rather than proving strict non-negativity for every possible XYZ input.

The unconstrained first row [0.8752, 0.2787, −0.1539] drives ρ clearly negative at the blue end; the PC row [0.6489, 0.3915, −0.0404] shrinks that negative entry so visible negative lobes almost disappear (checking the rounded four-decimal matrix from 380–780 nm at 1 nm steps still leaves a tiny −1.5×10⁻⁶ dip at 389 nm). On the index page’s cone chart, switching the main transform to Bianco PC 2010 removes the visible negative-lobe shading — the clearest difference from Bradford, CAT02 and Sharp.

The constraint consumes part of the fitting freedom, so this is not uniformly better than the unconstrained solution on every corresponding-colour dataset; it is chosen for the shape of its responses, when downstream processing (gamut mapping, the powers and logarithms inside appearance models) would rather not meet a negative cone response. It is still a linear 3×3 transform acting on tristimulus values, and it does not address metamerism.

White-point mapping is as exact as any other transform here: the D65 → D50 equivalent matrix at D = 1 is shown above.

Sources

  1. Bianco, S., & Schettini, R. (2010). Two new von Kries based chromatic adaptation transforms found by numerical optimization. Color Research & Application, 35(3), 184–192.